Acoustic Resilient Composite Floor Battens
Availability: Contact Us POA
Add to Compare
A Revit / BIM Family object file is available for this product.
Shallow and Deep - Acoustic Resilient Composite Floor Battens
USES | BENEFITS |
|
|
The Isocheck shallow batten system is designed to reduce sound transmission through a concrete structural sub-floor and consists of a layer of 13mm LRC foam bonded to a softwood batten.
When installed as part of a complete party floor construction it enables a concrete floor to meet the sound transmission standards of ADE 2003 (amended 2004). Should the requirement be for a batten height other than that detailed on this page please contact us for further advice of suitability and availability.
Product Data
- Overall batten size: 2400mm x 45mm x 45mm*
- Resilient layer thickness: 8mm
- Resilient layer: X-link Isopol
* alternative batten depths are available 54mm, 61mm and 70mm or custom to special order.
Performance
Treated floor meets with the descriptive FFT3, typically within Robust Detail E-FC-2. Using deeper battens (min. 70mm) would conform to FFT1 within E-FC-2 and E-FC-7.
- 18mm or 22mm chipboard deck
- Isocheck shallow battens @ 400mm max. centres
- min. 250mm in-situ concrete floor slab, 2400kg/m³ min density
- min 40mm, 80kg/m² screed applied directly to slab
- Suitable RD approved metal ceiling system
- Acoustic flanking band reduces the impact vibration leaking via structural walls and assists in reducing airborne and impact sound paths
Treated floor meets with the descriptive FFT3, typically within Robust Detail E-FC-1. Using deeper battens (min. 70mm) would conform to FFT1 within E-FC-1 and E-FC-7.
- 18mm or 22mm chipboard deck
- Isocheck shallow battens @ 400mm max. centres
- min 40mm, 80kg/m² screed applied directly to slab
- min. 150mm hollow core concrete plank (300kg/m²)
- Suitable RD approved metal or timber ceiling system
- Acoustic flanking band reduces the impact vibration leaking via structural walls and assists in reducing airborne and impact sound paths
Specification
The acoustic floor shall be:
Isocheck Shallow Batten, by Custom Audio Designs Ltd, 5 Ridgeway Office Park, Bedford Road, Petersfield, Hampshire, GU32 3QF and installed in accordance with manufacturer's instructions / recommendations.
EcoCheck Deep Batten system is designed to reduce sound transmission through timber floors within a timber framed structure.
EcoCheck Deep Batten consists of a batten bonded to 15mm LRAC. When installed as part of a complete party floor construction it enables a timber floor to meet the sound transmission standards of ADE 2003 (amended 2004).
Should the requirement be for a batten height higher than that detailed here please contact us for further technical advice and suitability.
Product Data
- Overall batten size: 1800mm x 45mm x 75mm OA
- Resilient layer thickness: Down to approx. 13mm under normal domestic load
- Resilient layer: 15mm LRAC
Performance
Treated floor meets with the descriptive FFT1, typically within Robust Details E-FT-1 and E-FT-2 and E-FT-3.
- 18mm (min) T&G chipboard and 19mm plasterboard plank
- Ecocheck deep battens @ 400mm max. centres perpendicular to the joists
- min. 60mm, 45kg/m³ mineral wool between battens
- min. 15mm thick floor decking
- min. 240mm timber I-joists at max. 400mm centres
- min. 100mm thick, 45kg/m³ mineral wool between joists
- min. 24kg/m² double boarded ceiling on resilient bars perpendicular to joists
- Acoustic flanking band reduces the impact vibration leaking via structural walls and assists in reducing airborne and impact sound paths
Performance
Treated floor meets with the descriptive FFT1, typically within Robust Details E-FT-1 and E-FT-2 and E-FT-3.
- 18mm (min) T&G chipboard and 19mm plasterboard plank
- Ecocheck deep battens @ 400mm max. centres
- min. 60mm, 45kg/m³ mineral wool between battens
- min. 11mm thick OSB floor decking
- min. 220mm solid timber joists at max. 400mm centres
- min. 100mm thick, 45kg/m³ mineral wool between joists
- min. 24kg/m² double boarded ceiling on resilient bars perpendicular to joists
- Acoustic flanking band reduces the impact vibration leaking via structural walls and assists in reducing airborne and impact sound paths
Specification
The acoustic floor shall be:
Ecocheck Deep Batten, by Custom Audio Designs Ltd, 5 Ridgeway Office Park, Bedford Road, Petersfield, Hampshire, GU32 3QF and installed in accordance with manufacturer's instructions / recommendations.
Use the resilient composite floor battens in conjunction with our Acoustic flanking strip to ensure your floor is fully isolated.
GENERAL DATA | ||||||
Product | Minimum Void Height | Typical Application | ||||
Part Code | Height | Width | Length | Timber (RSD) | Concrete (RSD) | |
AB30 | 45mm | 45mm | 1800mm | 45mm | E-FC-1, E-FC-2, E-FC-7 | |
AB40 | 50mm | 45mm | 1800mm | 45mm | E-FC-1, E-FC-2, E-FC-7 | |
AB70 | 75mm | 45mm | 1800mm | 70mm | E-FT-1, E-FT-2, E-FT-3, E-FS-4, E-FS-2 |
Write a review
Your Name:Your Review: Note: HTML is not translated!
Rating: Bad Good
Enter the code in the box below: